Matthew J Allen -United States Of America

Address Show details Email Show details
Share |

Summary Information

  • The Journal of bone and joint surgery. American volume (1)
  • Veterinary surgery : VS : the official journal of the American College of Veterinary Surgeons (1)
8,306,749
Maven is an online database of international healthcare professionals. Records are downloadable to Excel or in-house database, with email, postal address and phone/fax contacts.

To view and export full contact details of healthcare professionals you must subscribe to Maven Semantic. To learn more please request a call from our team:

Sources

Evaluation of the safety of a novel knee load-bypassing device in a sheep model.
(2012)
Journal - The Journal of bone and joint surgery. American volume (United States )

Abstract :

Unloading treatments for osteoarthritis of the knee, such as valgus braces, have been shown to reduce medial joint-loading and pain. The purpose of this preclinical study was to investigate the tissue response to an extracapsular implantable device (KineSpring System; Moximed, Hayward, California) that is designed to reduce loading across the medial compartment of the knee.Eleven sheep were implanted with the KineSpring System, consisting of bases secured to the medial femoral and tibial cortices with bone screws and also consisting of a joint-spanning load-absorber composed of a piston and spring assembly inside a polymeric sheath. In nine sheep, titanium alloy washers with either an uncoated or a plasma-sprayed titanium-hydroxyapatite (TPS-HA) coated undersurface were fixed with screws to the contralateral femur and tibia to investigate the effects of surface treatment on extracortical bone apposition. The functionality of the KineSpring System was assessed by fluoroscopy, tissue response was determined by gross and microscopic histology, and implant fixation was determined by radiography, microradiography, and histomorphometry at four, twelve, twenty-six, and fifty-two weeks.The function of the KineSpring System was confirmed in all sheep. Seventeen of eighteen TPS-HA coated bases and thirty-six of thirty-six washers had stable bone fixation; one coated base was loose with evidence of infection. At four weeks, there was an early, expected inflammatory response, but this response resolved by twelve weeks and a pseudosynovial membrane formed around the sheath. Bone apposition increased over time for the TPS-HA coated bases and for uncoated washers (p < 0.05). There was good apposition of the TPS-HA coated washers even at early time points, with no subsequent increase in apposition over time.The KineSpring System demonstrated safety in a simulated use model for periods of up to fifty-two weeks. Screws result in stable implant fixation and TPS-HA coating allows for early and long-lasting cortical bone apposition and integration.This implant warrants further investigation as a means of reducing medial compartment loading and pain in patients with osteoarthritis of the knee.

ISSN : 1535-1386
Cemented total knee replacement in 24 dogs: surgical technique, clinical results, and complications.
(2009)
Journal - Veterinary surgery : VS : the official journal of the American College of Veterinary Surgeons (United States )

Abstract :

OBJECTIVE: To characterize the performance of cemented total knee replacement (TKR) in dogs. STUDY DESIGN: Preclinical research study. ANIMALS: Skeletally mature, male Hounds (25-30 kg; n=24) with no preexisting joint pathology. METHODS: Dogs had unilateral cemented TKR and were evaluated at 6, 12, 26, or 52 weeks (6 dogs/time point) by radiography, bone density analysis, visual gait assessment, and direct measurement of thigh circumference and stifle joint range of motion as indicators of functional recovery. At study end, the stability of the cemented tibial component was determined by destructive mechanical testing. RESULTS: Joint stability was excellent in 16 dogs (67%) and good in 8 dogs. None of the tibial components had evidence of migration or periprosthetic osteolysis whereas 1 femoral component was loose at 52 weeks. There was an early and significant decrease in tibial bone density, likely because of disuse of the operated limb. Dogs returned to full activity by 12 weeks. The tibial cement-bone interface maintained its strength over 52 weeks. CONCLUSIONS: Cement provides stable fixation of the tibial component in canine TKR. CLINICAL RELEVANCE: Cemented TKR yields adequate clinical function and stifle joint excursion in the dog. Clinical studies are needed to determine the long-term fate of cemented TKR implants, to assess the influence of implant design on implant fixation and wear, and to obtain objective functional data.

ISSN : 1532-950X


Loading ...